Senin, 25 Juli 2011

heat shrink cable accessories


Product Range





Heat Shrinkable Molded shapes
  • End Caps
  • Anode Caps
  • Breakouts
    • Low Voltage Breakouts
    • Medium Voltage Breakouts
    • Conductive Breakouts
  • Boots
    • Medium Voltage Right Angle
    • Medium Voltage Straight Boots
  • Sheds
    • High Voltage Single Sheds
    • High Voltage Triple Sheds
Heat Shrinkable Extruded Products
  • Thin Wall Tubes
  • Medium Wall Tubes (LVT)
  • Medium Wall Tubes (NTT)
Heat Shrinkable System Products
  • Heat Shrinkable Terminations
  • Heat Shrinkable Joints                           


TERMINATION


SCOTCH CAST -  TERMINATION KITS
PST Cable seal – EPDM Rubber ( Up to 15kv )
( Indoor Type Only )




 PST CABLE SEAL EPDM RUBBERCABLE DIAMAX DIASIZE (sqmm)
   92E-8551-X-IN33613 X 50
   92E-8552-X-IN33613 X 90
   92E-8553-X-IN33613 X 150
   92E-8554-X-IN45783 X 185
   92E-8555-X-IN601063 X 240 - 500
   92E-8551-X-IN33613 X 1 X 50
   92E-8552-X-IN33613 X 1 X  90
   92E-8553-X-IN33613 X 1 X 150
   92E-8554-X-IN45783 X 1 X 185
  92E-8555-X-IN60
106
3 X 1 X 240 - 500


QT 11 HYBRID TERMINATION SERIES
Heat Shrink Rejacketing Tube And Cold Shrink Silicon Tube Skirt
Single Three Core cable Type





PRODUCT KIT NUMBERinsulation outdoor rangejacket outdoor rangesize sqmmvoltage range kv
QT II (J) 4S - 32H16 - 25 mm38 - 68 mm35 - 1506 - 15 Outdoor
QT II (K) 4S - 32H21 - 3255 - 85185 - 3006 - 15 Outdoor
QT II (L) 4S - 32H27 - 4165 - 904006 - 15 Outdoor
QT II (J) 4S - 32H16 - 2538 - 6835 - 9515.1 - 25 Indoor
QT II (K) 4S - 32H21 - 3255 - 85120 - 18515.1 - 25 indoor
QT II (L) 4S - 32H27 - 41165 - 90240 - 40015.1 - 25 Indoor
QT II (J) 6S - 32H18 - 2538 - 7035 - 9515.1 - 25 Outdoor
QT II (K) 6S - 32H23 - 3255 - 85120 - 18515.1 - 25 Outdoor
QT II (L) 6S - 32H28 - 2865 - 90240 - 40015.1 - 25 Outdoor
QT II (M) 6S - 32H35 - 4595 - 10550015.1 - 25 Outdoor
QT II (K) 6S - 32H23 - 3255 - 8550 - 95Up To 35 Indoor
QT II (L) 6S - 32H28 - 3865 - 90120 - 185Up To 35 Indoor
QT II (M) 6S - 32H35 - 4575 - 105240 - 400Up To 35 Indoor
QT II (K) 8S - 32H23 - 3255 - 8550 - 95Up To 35 Outdoor
QT II (L) 8S - 32H28 - 3865 - 90120 - 185Up To 35 Outdoor
QT II (M) 8S - 32H35 - 4575 - 115240 - 400Up To 35 Outdoor





QT 11 HYBRID TERMINATION SERIES
Heat Shrink Rejacketing Tube And Cold Shrink Silicon Tube Skirt
Three Single Core cable Type





PRODUCT KIT NUMBERinsulation outdoor rangejacket outdoor rangesize sqmmvoltage range kv
QT II (J) 4S - 32H16 - 2538 - 6835 - 1506 - 15 Outdoor
QT II (K) 4S - 32H21 - 3255 - 85185 - 3006 - 15 Outdoor
QT II (L) 4S - 32H27 - 4165 - 904006 - 15 Outdoor
QT II (J) 4S - 32H16 - 2538 - 6835 - 9515.1 - 25 Indoor
QT II (K) 4S - 32H21 - 3255 - 85120 - 18515.1 - 25 Indoor
QT II (L) 4S - 32H27 - 41165 - 90240 - 40015.1 - 25 Indoor
QT II (J) 6S - 32H18 - 2538 - 7035 - 9515.1 - 25 Outdoor
QT II (K) 6S - 32H23 - 3255 - 85120 - 18515.1 - 25 Outdoor
QT II (L) 6S - 32H28 - 2865 - 90240 - 40015.1 - 25 Outdoor
QT II (M) 6S - 32H35 - 4595 - 10550015.1 - 25 Outdoor
QT II (K) 6S - 32H23 - 3255 - 8550 - 95Up To 35 Indoor
QT II (L) 6S - 32H28 - 3865 - 90120 - 185Up To 35 Indoor
QT II (M) 6S - 32H35 - 4575 - 105240 - 400Up To 35 Indoor
QT II (K) 8S - 32H23 - 3255 - 8550 - 95Up To 35 Outdoor
QT II (L) 8S - 32H28 - 3865 - 90120 - 185Up To 35 Outdoor
QT II (M) 8S - 32H35 - 4575 - 115240 - 400Up To 35 Outdoor

Heat Shrink Joints System upto 36kV

Governing Standards:
DIN VDE 0278/ CENELEC "POWER CABLE ACCESSORIES WITH RATED VOLTAGE UP TO 30 kV (Um = 36 kV)", IEEE 48-1990:  HIGH VOLTAGE ALTERNATING - CURRENT CABLE TERMINATIONS.
Type Testing
Ikebana MV Joint systems are type tested as per DIN VDE 0278/ CENELEC standards in independent recognized laboratories. The type test reports will be available on request.
Parts of the Joint System:
1. Insulation Build-Up
Restoration of insulation and screen over the inline connector effected by multiple layers of insulating tubes of high dielectric strength and a semi-conductive tube.

2. Impact Resistance
Protection to inner HV parts from impacts provided by wrap around steel mat.

3. Stress Control
High electrical stress near screen-cut section avoided by stress control tube with controlled impedance characteristics, which remain constant over the range of conductor operating temperature.

Electrical stresses over the in-line connector limited by application of high permittivity mastic.

4. Armor Bond
Proven electrical continuity arrangement provided for limiting temperature rise of armor bonding assembly, during flow of earth fault currents.

   CHECK PRICE & STOCK   PIN : 224AC1CE

   BEST PRICE   
   Untuk mendapatkan harga terbaik kami, silahkan email permintaan anda ke:            hnelectrical@yahoo.co.id